Metal Molding and Casting (Foundries) Effluent Guidelines

""EPA promulgated the Metal Molding and Casting (MMC) Effluent Guidelines and Standards (40 CFR Part 464) in 1985. MMC facilities discharge process wastewater directly to surface waters or indirectly to surface waters through publicly owned treatment worksHelppublicly owned treatment worksA treatment works that is owned by the state or municipality. (POTW). The MMC regulation covers 28 process segments (processes such as casting quench, grinding scrubber, mold cooling) in four subcategories: Aluminum Casting, Copper Casting, Ferrous Casting, and Zinc Casting. The Effluent Guidelines are incorporated into NPDES permits for direct dischargers, and permits or other control mechanisms for indirect dischargers (see Pretreatment Program).

On this page:

What is Metal Molding and Casting?

The facilities covered by the MMC regulation are often referred to as Foundries. A foundry produces metal castings from either ferrous or non-ferrous alloys. Metals are turned into parts by melting the metal into a liquid, pouring or injecting the metal in a mold, with the cavity of the mold representing, within close tolerances, the dimension of the finished product. One of the major advantages of this process is that intricate metal shapes, which are not easily obtained by any other method of fabrication, can be produced. Another advantage is the rapid translation of a projected design into a finished article.

Facilities Covered

Covered facilities include both "job shops"—plants that sold 50 percent or more of their production to customers outside the corporate entity and "captive plants"—plants that sold 50 percent or more of their products internally or were used within the corporate entity. The scope of the regulated industry, as reported here, reflects the Agency's data at the time the regulation was issued in 1985, which in turn was based on data from the late 1970s.

At the time of promulgation EPA estimated that about 700 plants generated and discharged process wastewater. The facilities covered included both direct dischargers and plants that discharge to POTWs. The regulations for direct dischargers—those who discharge to surface waters—cover both continuous and intermittent discharges, although the effluent limitations vary by that distinction.

For indirect dischargers—those who discharge to POTWs, which is the larger number of plants—the effluent limits apply only to continuous dischargers. POTWs may elect to establish concentration-based standards for non-continuous discharges; details and instructions are included in the rulemaking support documents. Special care needs to be given to potential for overlap of applicability to Metal Molding and Casting facilities with other categories, such as Metal Finishing (note particularly the presence or absence of six "core operations" that must be present for operations to be covered by the Metal Finishing regulations, 40 CFR Part 433), Aluminum Forming (40 CFR Part 467), and Copper Forming (40 CFR Part 468). Please review the MMC Development Document regarding process operations and associated wastewaters covered in each subcategory (Sections 3 and 5) and the Appendices, notably Appendix C.

Top of Page


Effluent Limitations and Technologies

For three of the process segments, the technology basis of the regulations is "no discharge of process wastewater pollutants." For the remaining 25 segments, the regulations are based on a combination of technologies such as high rate recycle, oil skimming, lime precipitation and settling, and filtration. Examples of the pollutants with effluent limits for Foundries are total suspended solids, phenols, copper, lead, and zinc, and also a bulk parameter (oil and grease) for monitoring total toxic organics (TTO) in all subcategories for indirect dischargers (see 40 CFR 464.03(a)).

Top of Page


Rulemaking History

  • Documents, including:
    • Final Rule: 50 FR 45212, 10/30/1985
    • Development Document
      Describes industry processes, pollutants generated, available control and treatment technologies, the technical basis for the final rule, and costs of the rule. Includes guidance for implementing the regulations (Appendix C).
    • Notice of Data Availability: 48 FR 52604, 11/21/1983
    • Proposed Rule: 47 FR 51512, 11/15/1982

Top of Page


Additional Information

For additional information regarding the MMC Effluent Guidelines, please contact Phillip Flanders (flanders.phillip@epa.gov) or 202-566-8323.

Top of Page